Frequency; 40 MHz to 40 GHz. Lightning Family Microwave and Millimeter Wave VNAs. Flexible test port configuration, multiple upgrade paths, high stability and reliability. Simple Type: Network Analyzers
The Lightning D series microwave and millimeter-wave Vector Network Analyzers encompass a wide range of high performance component and system test tools designed to address the growing needs of defense, satellite, radar, broadband communication, and optoelectronic component markets. Complete measurements solutions to 20, 40 and 65/67 GHz are available in microwave models 37x47D, 37x69D and 37x97D, respectively. And when configured with millimeter-wave modules, Lightning D series can be used for broadband applications covering 40 MHz to 110 GHz in a single coaxial sweep, or up to 500 GHz in waveguide.
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Data Averaging: Point-by-point (default) {up to 4096}, Sweep-by-Sweep
- Data Points: 1601 maximum or N discrete data points where 2 =N =1601.
- Domains: Frequency Domain, CW Draw, and optional High Speed Time (Distance) Domain.
- Graph Types: Log Magnitude, Phase, Log Magnitude and Phase, Smith Chart (Impedance), Smith Chart (Admittance), Linear Polar, Log Polar, Group Delay, Linear Magnitude, Linear Magnitude and Phase, Real,
- IF Bandwidth: 10 kHz to 10 Hz
- Limits Lines: Either single or segmented limit lines can be displayed. Two limit lines are available for each trace.
- Measurement Parameters: S11, S21, S22, S12 User-defined combinations of a1, a2, b1, and b2.
- Reference Plane: Can be entered in time or in distance (when the dielectric constant is entered). Automatic reference plane feature adds the correct electrical length (delay) compensation. Software co
- Segmented Limits: A total of 20 segments (10 upper and 10 lower) can be generated per data trace. Complete segmented traces can be offset in both frequency and amplitude.
- Single Limit Readouts: Interpolation algorithm determines the exact intersection frequencies of test data and limit lines.
- Test Limits: Both single and segmented limits can be used for PASS/FAIL testing. The active channel's PASS or FAIL status is indicated on the display after each sweep. In addition, PASS/FAIL status is
- Tune Mode: Tune Mode optimizes sweep speed in tuning applications by updating forward S-parameters more frequently than reverse ones. This mode allows the user to select the ratio of forward sweeps to
Specifications